Staff Doses in Interventional Radiology: A National Survey. (Registro nro. 13117)

000 -CABECERA
Campo de control de longitud fija 02353na a2200229 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control H12O
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20201021062601.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 130622s2012 xxx||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1860
Nombre de persona Martínez Gómez, Luis Carlos
Término indicativo de función Radiofísica Hospitalaria
245 00 - MENCIÓN DE TÍTULO
Título Staff Doses in Interventional Radiology: A National Survey.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Journal of Vascular and Interventional Radiology,
Fecha de publicación distribución etc. 2012
300 ## - DESCRIPCIÓN FÍSICA
Extensión 23(11):1496-501.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Sánchez RM, Vano E, Fernández JM, Rosales F, Sotil J, Carrera F, et al. Staff doses in interventional radiology: a national survey. J Vasc Interv Radiol. 2012 Nov;23(11):1496-501.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 22832138
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 25 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Purpose: To present the results of occupational radiation doses investigated through a national survey promoted by the National Society of Interventional Radiology in Spain. Materials and Methods: The monthly dosimetric records of 28 interventional radiologists from 10 hospitals were analyzed and filtered to remove inconsistent dosimeter readings. The evaluation of the results includes different workloads as well as different radiation protection habits. Results: Poor use of personal dosimetry by some interventional radiologists was brought to light. Most professionals do not use an over-apron dosimeter as recommended by the International Commission on Radiological Protection. Ceiling-suspended protective screens are used irregularly in many cases. All interventionalists perform digital subtraction angiographic imaging from a control room in more than 80% of procedures. The maximum monthly doses recorded were 3.8 mSv under the apron, 20.2 mSv over the apron, and 63.1 mSv to the hands. Conclusions: For under-apron and hand readings, extrapolated median values were below 30% of annual dose limits, but in the case of over-apron readings, the extrapolated median dose was higher than the newly recommended limit for the eye lens of 20 mSv per year. This study mainly highlights the need to use radiation protection tools and personal dosimeters to protect staff and monitor eye lens doses.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 465
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Radiofísica Hospitalaria
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc13117.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Suprimido en OPAC Público
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2017-04-10 PC13117 2017-04-10 2017-04-10 Artículo

Con tecnología Koha