Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country. (Registro nro. 16216)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC16216 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20210406113114.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 210201b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1070 |
Nombre de persona | Rodríguez Muñoz, Sarbelio |
Término indicativo de función | Aparato Digestivo |
245 00 - MENCIÓN DE TÍTULO | |
Título | Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Revista española de enfermedades digestivas : órgano oficial de la Sociedad Española de Patología Digestiva, |
Fecha de publicación distribución etc. | 2014 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 106(2):98-102. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver_ De-la-Peña J, Calderón Á, Esteban JM, López-Rosés L, Martínez-Ares D, Nogales Ó et al. Experimental study of hybrid-knife endoscopic submucosal dissection (ESD) versus standard ESD in a Western country. Rev Esp Enferm Dig. 2014 Feb;106(2):98-102. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 24852735 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 19 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Background: Endoscopic submucosal dissection (ESD) is an effective but time-consuming treatment for early neoplasia that requires a high level of expertise. Objective: The objective of this study was to assess the efficacy and learning curve of gastric ESD with a hybrid knife with highpressure water jet and to compare with standard ESD. Material and methods: We performed a prospective nonsurvival animal study comparing hybrid-knife and standard gastric ESD. Variables recorded were: Number of en-bloc ESD, number of ESD with all marks included (R0), size of specimens, time and speed of dissection and adverse events. Ten endoscopists performed a total of 50 gastric ESD (30 hybrid-knife and 20 standard). Results: Forty-six (92 %) ESD were en-bloc and 25 (50 %) R0 (hybrid-knife: n = 13, 44 %; standard: n = 16, 80 %; p = 0.04). Hybrid-knife ESD was faster than standard (time: 44.6 ± 21.4 minutes vs. 68.7 ± 33.5 minutes; p = 0.009 and velocity: 20.8 ± 9.2 mm2/min vs. 14.3 ± 9.3 mm2/min (p = 0.079). Adverse events were not different. There was no change in speed with any of two techniques (hybrid-knife: From 20.33 ± 15.68 to 28.18 ± 20.07 mm2/min; p= 0.615 and standard: From 6.4 ± 0.3 to 19.48 ± 19.21 mm2/min; p = 0.607). The learning curve showed a significant improvement in R0 rate in the hybrid-knife group (from 30 % to 100 %). Conclusion: despite the initial performance of hybrid-knife ESD is worse than standard ESD, the learning curve with hybridknife ESD is short and is associated with a rapid improvement. The introduction of new tools to facilitate ESD should be implemented with caution in order to avoid a negative impact on the results. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 273 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Medicina del Aparato Digestivo |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16216.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2021-02-01 | PC16216 | 2021-02-01 | 2021-02-01 | Artículo |