Biblioteca Hospital 12 de Octubre

Estudio de seguridad de la biopsia renal percutánea con aguja de calibre 16 G. (Registro nro. 16578)

000 -CABECERA
Campo de control de longitud fija nab a22 7a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC16578
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20210811104835.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 210804b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente spa, eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2375
Nombre de persona Guerrero Ramos, Félix
Término indicativo de función Urología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 485
Nombre de persona Villacampa Aubá, Felipe
Término indicativo de función Urología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2445
Nombre de persona JIménez Alcaide, Estíbaliz
Término indicativo de función Urología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2594
Nombre de persona García González, Lucía
Término indicativo de función Urología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1795
Nombre de persona Rosa Kehrman, Federico de la
Término indicativo de función Urología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2936
Nombre de persona Ospina Galeano, Irma Amparo
Término indicativo de función Urología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1692
Nombre de persona Rodríguez Antolín, Alfredo
Término indicativo de función Urología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1929
Nombre de persona Passas Martínez, Juan
Término indicativo de función Urología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 946
Nombre de persona Díaz González, Rafael
Término indicativo de función Urología
245 00 - MENCIÓN DE TÍTULO
Título Estudio de seguridad de la biopsia renal percutánea con aguja de calibre 16 G.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Actas urológicas españolas,
Fecha de publicación distribución etc. 2014
300 ## - DESCRIPCIÓN FÍSICA
Extensión 38(9):584-8.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Guerrero Ramos F, Villacampa Aubá F, Jiménez Alcaide E, García González L, Ospina Galeano IA, de la Rosa Kehrmann F et al. Estudio de seguridad de la biopsia renal percutánea
con aguja de calibre 16 G. Actas Urol Esp. 2014 Nov;38(9):584-8.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 24533921
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 35 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Introduction and objective: The development of percutaneous renal biopsy as a routinary diagnostic procedure for renal masses is topic of discussion for the last few years. However, this technique has been associated with some complications, although infrequent, and morbidity. Our objective is to carry out a descriptive study about complications and outcomes of orthotopic kidney biopsies with 16 G needle.
Material and methods: A retrospective review of 180 orthotopic ultrasound-guided renal biopsies performed in our service among January 2008 to May 2010 was carried out. The procedure was developed using an automated biopsy gun (16G needle). Multiple clinical variables, early post-procedure complications and its management were collected. Complication rates as well as the relationship between risk factors and occurrence of complications were studied.
Results: Mean age was 55.8 years. The average number of biopsy cylinders per intervention was 2.49. The overall complication rate was 5.6%. An interventionist attitude derived from complication of the procedure was necessary in only 3 patients (1.67%). No surgical interventions were required and no death as consequence of procedure was registered. No relationship between hypertension (P=.09) previous anticoagulation (P=.099) or previous antiaggregation (P=.603) and complications were demonstrated. In 2.8% of biopsies the material obtained was insufficient for diagnosing.
Conclusions: Percutaneous ultrasound-guided renal biopsy with 16G needle is a safe technique with high diagnostic performance.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 220
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Urología
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16578.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2021-08-04 PC16578 2021-08-04 2021-08-04 Artículo

Con tecnología Koha