Estudio de seguridad de la biopsia renal percutánea con aguja de calibre 16 G. (Registro nro. 16578)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC16578 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20210811104835.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 210804b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | spa, eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2375 |
Nombre de persona | Guerrero Ramos, Félix |
Término indicativo de función | Urología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 485 |
Nombre de persona | Villacampa Aubá, Felipe |
Término indicativo de función | Urología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2445 |
Nombre de persona | JIménez Alcaide, Estíbaliz |
Término indicativo de función | Urología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2594 |
Nombre de persona | García González, Lucía |
Término indicativo de función | Urología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1795 |
Nombre de persona | Rosa Kehrman, Federico de la |
Término indicativo de función | Urología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2936 |
Nombre de persona | Ospina Galeano, Irma Amparo |
Término indicativo de función | Urología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1692 |
Nombre de persona | Rodríguez Antolín, Alfredo |
Término indicativo de función | Urología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1929 |
Nombre de persona | Passas Martínez, Juan |
Término indicativo de función | Urología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 946 |
Nombre de persona | Díaz González, Rafael |
Término indicativo de función | Urología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Estudio de seguridad de la biopsia renal percutánea con aguja de calibre 16 G. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Actas urológicas españolas, |
Fecha de publicación distribución etc. | 2014 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 38(9):584-8. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Guerrero Ramos F, Villacampa Aubá F, Jiménez Alcaide E, García González L, Ospina Galeano IA, de la Rosa Kehrmann F et al. Estudio de seguridad de la biopsia renal percutánea con aguja de calibre 16 G. Actas Urol Esp. 2014 Nov;38(9):584-8. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 24533921 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 35 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Introduction and objective: The development of percutaneous renal biopsy as a routinary diagnostic procedure for renal masses is topic of discussion for the last few years. However, this technique has been associated with some complications, although infrequent, and morbidity. Our objective is to carry out a descriptive study about complications and outcomes of orthotopic kidney biopsies with 16 G needle. Material and methods: A retrospective review of 180 orthotopic ultrasound-guided renal biopsies performed in our service among January 2008 to May 2010 was carried out. The procedure was developed using an automated biopsy gun (16G needle). Multiple clinical variables, early post-procedure complications and its management were collected. Complication rates as well as the relationship between risk factors and occurrence of complications were studied. Results: Mean age was 55.8 years. The average number of biopsy cylinders per intervention was 2.49. The overall complication rate was 5.6%. An interventionist attitude derived from complication of the procedure was necessary in only 3 patients (1.67%). No surgical interventions were required and no death as consequence of procedure was registered. No relationship between hypertension (P=.09) previous anticoagulation (P=.099) or previous antiaggregation (P=.603) and complications were demonstrated. In 2.8% of biopsies the material obtained was insufficient for diagnosing. Conclusions: Percutaneous ultrasound-guided renal biopsy with 16G needle is a safe technique with high diagnostic performance. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 220 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Urología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16578.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2021-08-04 | PC16578 | 2021-08-04 | 2021-08-04 | Artículo |