Determinants of false-negative results in non-small-cell lung cancer staging by endobronchial ultrasound-guided needle aspiration. (Registro nro. 16923)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC16923 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20220622102422.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 220622b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1193 |
Nombre de persona | García Luján, Ricardo |
Término indicativo de función | Neumología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1191 |
Nombre de persona | Miguel Poch, Eduardo de |
Término indicativo de función | Neumología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Determinants of false-negative results in non-small-cell lung cancer staging by endobronchial ultrasound-guided needle aspiration. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, |
Fecha de publicación distribución etc. | 2015 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 47(4):642-7. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Sanz Santos J, Serra M, Gallego M, Montón C, Cosio B, Sauleda J et al. Determinants of false-negative results in non-small-cell lung cancer staging by endobronchial ultrasound-guided needle aspiration. Eur J Cardiothorac Surg. 2015 Apr;47(4):642-7. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 25005839 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 25 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Objectives: False-negative results of endobronchial ultrasound-guided transbronchial needle aspiration in non-small-cell lung cancer staging have shown significant variability in previous studies. The aim of this study was to identify procedure- and tumour-related determinants of endobronchial ultrasound-guided transbronchial needle aspiration false-negative results. Methods: We conducted a prospective study that included non-small-cell lung cancer patients staged as N0/N1 by endobronchial ultrasound-guided transbronchial needle aspiration and undergoing therapeutic surgery. The frequency of false-negative results in the mediastinum was calculated. Procedure-related, first, and tumour-related, second, determinants of false-negative results in stations reachable and non-reachable by endobronchial ultrasound were determined by multivariate logistic regression. Results: False-negative endobronchial ultrasound-guided transbronchial needle aspiration results were identified in 23 of 165 enrolled patients (13.9%), mainly in stations reachable by endobronchial ultrasound (17 cases, 10.3%). False-negative results were related to the extensiveness of endobronchial ultrasound sampling: their prevalence was low (2.4%) when sampling of three mediastinal stations was satisfactory, but rose above 10% when this requirement was not fulfilled (P = 0.043). In the multivariate analysis, abnormal mediastinum on computer tomography/positron emission tomography [odds ratio (OR) 7.77, 95% confidence interval (CI) 2.19-27.51, P = 0.001] and extensiveness of satisfactory sampling of mediastinal stations (OR 0.37, 95% CI 0.16-0.89, P = 0.026) were statistically significant risk factors for false-negative results in stations reachable by endobronchial ultrasound. False-negative results in non-reachable nodes were associated with a left-sided location of the tumour (OR 10.11, 95% CI 1.17-87.52, P = 0.036). Conclusions: The presence of false-negative ultrasound-guided transbronchial needle aspiration results were observed in nearly 15% of non-small-cell lung cancer patients but in only 3% when satisfactory samples were obtained from three mediastinal stations. False-negative results in stations reachable by endobronchial ultrasound were associated with the extensiveness of sampling, and in stations out of reach of endobronchial ultrasound with left-sided tumours. These results suggest that satisfactory sampling of at least three mediastinal stations by EBUS-TBNA may be a quality criterion to be recommended for EBUS-TBNA staging. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 88 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Neumología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16923.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2022-06-22 | PC16923 | 2022-06-22 | 2022-06-22 | Artículo |