Determinants of false-negative results in non-small-cell lung cancer staging by endobronchial ultrasound-guided needle aspiration. (Registro nro. 16923)

000 -CABECERA
Campo de control de longitud fija nab a22 7a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC16923
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20220622102422.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 220622b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1193
Nombre de persona García Luján, Ricardo
Término indicativo de función Neumología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1191
Nombre de persona Miguel Poch, Eduardo de
Término indicativo de función Neumología
245 00 - MENCIÓN DE TÍTULO
Título Determinants of false-negative results in non-small-cell lung cancer staging by endobronchial ultrasound-guided needle aspiration.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery,
Fecha de publicación distribución etc. 2015
300 ## - DESCRIPCIÓN FÍSICA
Extensión 47(4):642-7.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Sanz Santos J, Serra M, Gallego M, Montón C, Cosio B, Sauleda J et al. Determinants of false-negative results in non-small-cell lung cancer staging by endobronchial ultrasound-guided needle aspiration. Eur J Cardiothorac Surg. 2015 Apr;47(4):642-7.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 25005839
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 25 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Objectives: False-negative results of endobronchial ultrasound-guided transbronchial needle aspiration in non-small-cell lung cancer staging have shown significant variability in previous studies. The aim of this study was to identify procedure- and tumour-related determinants of endobronchial ultrasound-guided transbronchial needle aspiration false-negative results.
Methods: We conducted a prospective study that included non-small-cell lung cancer patients staged as N0/N1 by endobronchial ultrasound-guided transbronchial needle aspiration and undergoing therapeutic surgery. The frequency of false-negative results in the mediastinum was calculated. Procedure-related, first, and tumour-related, second, determinants of false-negative results in stations reachable and non-reachable by endobronchial ultrasound were determined by multivariate logistic regression.
Results: False-negative endobronchial ultrasound-guided transbronchial needle aspiration results were identified in 23 of 165 enrolled patients (13.9%), mainly in stations reachable by endobronchial ultrasound (17 cases, 10.3%). False-negative results were related to the extensiveness of endobronchial ultrasound sampling: their prevalence was low (2.4%) when sampling of three mediastinal stations was satisfactory, but rose above 10% when this requirement was not fulfilled (P = 0.043). In the multivariate analysis, abnormal mediastinum on computer tomography/positron emission tomography [odds ratio (OR) 7.77, 95% confidence interval (CI) 2.19-27.51, P = 0.001] and extensiveness of satisfactory sampling of mediastinal stations (OR 0.37, 95% CI 0.16-0.89, P = 0.026) were statistically significant risk factors for false-negative results in stations reachable by endobronchial ultrasound. False-negative results in non-reachable nodes were associated with a left-sided location of the tumour (OR 10.11, 95% CI 1.17-87.52, P = 0.036).
Conclusions: The presence of false-negative ultrasound-guided transbronchial needle aspiration results were observed in nearly 15% of non-small-cell lung cancer patients but in only 3% when satisfactory samples were obtained from three mediastinal stations. False-negative results in stations reachable by endobronchial ultrasound were associated with the extensiveness of sampling, and in stations out of reach of endobronchial ultrasound with left-sided tumours. These results suggest that satisfactory sampling of at least three mediastinal stations by EBUS-TBNA may be a quality criterion to be recommended for EBUS-TBNA staging.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 88
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Neumología
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16923.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2022-06-22 PC16923 2022-06-22 2022-06-22 Artículo

Con tecnología Koha