Biblioteca Hospital 12 de Octubre

Antiplatelet therapy versus observation in low-risk essential thrombocythemia with a CALR mutation. (Registro nro. 17555)

000 -CABECERA
Campo de control de longitud fija nab a22 7a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC17555
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20230703130120.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 230703b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1206
Nombre de persona Ayala Díaz, Rosa María
Término indicativo de función Hematología y Hemoterapia
245 00 - MENCIÓN DE TÍTULO
Título Antiplatelet therapy versus observation in low-risk essential thrombocythemia with a CALR mutation.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Haematologica,
Fecha de publicación distribución etc. 2016
300 ## - DESCRIPCIÓN FÍSICA
Extensión 101(8):926-31.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Alvarez Larrán A, Pereira A, Guglielmelli P, Hernández Boluda JC, Arellano Rodrigo E, Ferrer Marín F et al. Antiplatelet therapy versus observation in low-risk essential thrombocythemia with a CALR mutation. Haematologica. 2016 Aug;101(8):926-31.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 27175028
PMC4967571
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 18 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. The role of antiplatelet therapy as primary prophylaxis of thrombosis in low-risk essential thrombocythemia has not been studied in randomized clinical trials. We assessed the benefit/risk of low-dose aspirin in 433 patients with low-risk essential thrombocythemia (271 with a CALR mutation, 162 with a JAK2(V617F) mutation) who were on antiplatelet therapy or observation only. After a follow up of 2215 person-years free from cytoreduction, 25 thrombotic and 17 bleeding episodes were recorded. In CALR-mutated patients, antiplatelet therapy did not affect the risk of thrombosis but was associated with a higher incidence of bleeding (12.9 versus 1.8 episodes per 1000 patient-years, P=0.03). In JAK2(V617F)-mutated patients, low-dose aspirin was associated with a reduced incidence of venous thrombosis with no effect on the risk of bleeding. Coexistence of JAK2(V617F)-mutation and cardiovascular risk factors increased the risk of thrombosis, even after adjusting for treatment with low-dose aspirin (incidence rate ratio: 9.8; 95% confidence interval: 2.3-42.3; P=0.02). Time free from cytoreduction was significantly shorter in CALR-mutated patients with essential thrombocythemia than in JAK2(V617F)-mutated ones (median time 5 years and 9.8 years, respectively; P=0.0002) and cytoreduction was usually necessary to control extreme thrombocytosis. In conclusion, in patients with low-risk, CALR-mutated essential thrombocythemia, low-dose aspirin does not reduce the risk of thrombosis and may increase the risk of bleeding.

710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 297
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Hematología y Hemoterapia
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4967571/pdf/1010926.pdf
Acceso Acceso libre
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2023-07-03 PC17555 2023-07-03 2023-07-03 Artículo

Con tecnología Koha