Atrial Rate-Responsive Pacing and Incidence of Sustained Atrial Arrhythmias in Patients with Implantable Cardioverter Defibrillators. (Registro nro. 17573)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC17573 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20230718120825.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 230718b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2225 |
Nombre de persona | Fontenla Cerezuela, Adolfo |
Término indicativo de función | Cardiología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 158 |
Nombre de persona | Salguero Bodes, Rafael |
Término indicativo de función | Cardiología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1253 |
Nombre de persona | López Gil, María |
Término indicativo de función | Cardiología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1249 |
Nombre de persona | Arribas Ynsaurriaga, Fernando |
Término indicativo de función | Cardiología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Atrial Rate-Responsive Pacing and Incidence of Sustained Atrial Arrhythmias in Patients with Implantable Cardioverter Defibrillators. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Pacing and clinical electrophysiology : PACE, |
Fecha de publicación distribución etc. | 2016 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 39(6):548-56. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Fontenla A, Salguero R, Martínez Ferrer JB, Rodriguez A, Alzueta J, Garcia E et al. Atrial Rate-Responsive Pacing and Incidence of Sustained Atrial Arrhythmias in Patients with Implantable Cardioverter Defibrillators. Pacing Clin Electrophysiol. 2016 Jun;39(6):548-56. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 27001125 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 20 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Background: Atrial rate-responsive pacing (RRP) has proved to be safe in pacemaker recipients with chronotropic incompetence. Although RRP is available in all current implantable cardioverter defibrillators (ICDs), the outcomes of this pacing mode in ICD patients are unknown. The aim is to evaluate the relationship between atrial RRP and atrial arrhythmias in ICD recipients. Methods: Dual-chamber and triple-chamber ICD patients were included in this multicenter cohort study. Patients with permanent atrial fibrillation (AF) or VVI pacing mode were excluded. The number and duration of atrial tachycardia (AT)/AF episodes were assessed. Results: Data from 415 patients and 80,707 AT/AF episodes (median duration: 0.4 hours) were collected after a 21.3 ± 14.1-month follow-up. Atrial RRP was programmed in 90 (21.7%) patients and was associated with a higher atrial pacing percentage in the overall study population (51.2 ± 33.8% vs 18.4 ± 25.7%, P < 0.001) and to a higher ventricular pacing percentage among dual-chamber devices (22.3 ± 37.6% vs 9.3 ± 25%, P < 0.001). Independent factors associated with sustained AT/AF episodes (>23 hours) were previous AF (odds ratio [OR]: 7.98; 95% confidence interval [CI]: 4.11-15.47; P < 0.001) and atrial RRP (OR: 3.58; 95% CI: 1.82-7.03; P < 0.001). RRP was related to a lower sustained AT/AF episodes-free survival both in patients with a history of AF (43% vs 70%, P = 0.035) and without a history of AF (82% vs 97%, P = 0.004) at 2 years. Conclusions: Atrial RRP in ICD patients was related to a higher incidence of sustained atrial arrhythmias. This pacing mode may have an atrial proarrhythmic effect on ICD patients, especially among those with a history of AF. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 119 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Cardiología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc17573.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2023-07-18 | PC17573 | 2023-07-18 | 2023-07-18 | Artículo |