Spanish Pacemaker Registry. 10th Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2012). (Registro nro. 5189)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | 02082na a2200229 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC5189 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20210630062734.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 130622s2013 xxx||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 566 |
Nombre de persona | Coma Samartín, Raúl |
Término indicativo de función | Cardiología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Spanish Pacemaker Registry. 10th Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2012). |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Revista española de cardiología (English edition), |
Fecha de publicación distribución etc. | 2013 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 66(12):959-72. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Coma Samartín R, Ruiz Mateas F, Fidalgo Andrés ML, Leal del Ojo González J, Pérez Álvarez L. Spanish pacemaker registry. 10th official report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2012). Rev Esp Cardiol (Engl Ed). 2013 Dec;66(12):959-72. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 24774109 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 29 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Introduction and objectives: Our aim was to analyze the pacemaker implantations and replacements reported to the Spanish Pacemaker Registry in 2012 with special reference to the selection of pacing modes. Method: The analysis was based on information provided by the European Pacemaker Patient Identification Card. Results: Data were received from 115 hospitals, with a total of 12 856 cards. An estimated 745.8 pacemaker generators and 53.1 resynchronization devices were implanted per million population. Active fixation leads were implanted in more than 70% of the patients; of these leads, more than 20% were safe for use with magnetic resonance. The most common electrocardiographic indication for pacemaker implantation was atrioventricular block (56%). In all, 28% of the patients with sick sinus syndrome were paced in VVIR mode. Conclusions: The use of conventional pacemakers remained stable, whereas the implantation of resynchronization devices increased. Active fixation leads are now employed in most patients. The findings of this study confirm the higher incidence of implantation in men and at an earlier age due to the higher rate of conduction disorders. Age is a factor that influences the choice of the appropriate pacing mode. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 67 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Medicina Intensiva |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/5/pc5189.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Suprimido en OPAC | Público |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2018-07-03 | PC5189 | 2018-07-03 | 2018-07-03 | Artículo |