Resultados a medio plazo de dispositvos de drenaje para glaucoma en pacientes pediátricos. (Registro nro. 6939)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | 02661na a2200277 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | H12O |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20180417112621.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 130622s2012 xxx||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | spa |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
Nombre de persona | Barceló Mendiguchia, Ana |
9 (RLIN) | 1787 |
Numeración | |
Término indicativo de función | Oftalmología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 428 |
Nombre de persona | Gutiérrez Díaz, Esperanza |
Término indicativo de función | Oftalmología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
Nombre de persona | Mencía Gutiérrez, Enrique |
9 (RLIN) | 1786 |
Término indicativo de función | Oftalmología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
Nombre de persona | Tejada Palacios, Pilar |
9 (RLIN) | 1437 |
Término indicativo de función | Oftalmología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Resultados a medio plazo de dispositvos de drenaje para glaucoma en pacientes pediátricos. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Archivos de la Sociedad Española de Oftalmología, |
Fecha de publicación distribución etc. | 2012 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 87(2):38-43. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Colás-Tomás T, Gutiérrez-Díaz E, Tejada-Palacios P, Barceló-Mendiguchía A, Mencía-Gutiérrez E. Resultados a medio plazo de dispositvos de drenaje para glaucoma en pacientes pediátricos. Arch Soc Esp Oftalmol. 2012 Feb;87(2):38-43. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 22341357 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 19 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | PURPOSE: To evaluate the results and long-term complications of glaucoma drainage devices (GDD) in paediatric patients (0-15 years). METHODS: Retrospective cohort study was conducted on 17 implanted glaucoma drainage devices from July 1994 to April 2007 in 14 patients (17 eyes). In two patients (3 eyes) a Molteno GDD (MGDD) was implanted, and in 12 patients (14 eyes) an Ahmed GDD (AGDD) was used. We studied the demographic and glaucoma related patient data, as well as the probability of surgical success. The time which intraocular pressure (IOP) was controlled and the postoperative complications were also studied. RESULTS: Of the fourteen patients, 9 (64.28%) showed congenital glaucoma, and 5 (35.71%) aphakic glaucoma. The pre-aqueous drainage device median IOP was 29.82 mmHg (SD: 6.98), and 14.05 mmHg (SD: 7.57) postoperative. The median follow-up was 3.14 years (3 months-8.3 years). Success of aqueous drainage device was defined as an IOP less than 21 mmHg with or without medication on the last two follow-up visits, and without severe complications or further glaucoma surgery. Using a Kaplan Meier analysis there was success in 76%, 63% and 55% at the six months, 1-3 years and 4-8 years respectively. The GDD was a failure in 41.17%. CONCLUSIONS: GDDs are a good surgery option for refractory paediatric glaucoma when other surgery procedures have failed or have bad prognosti. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 223 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Oftalmología |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 446 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Pediatría-Neonatología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/6/pc6939.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Suprimido en OPAC | Público |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2016-11-25 | PC6939 | 2016-11-25 | 2016-11-25 | Artículo |