Revisión de las reacciones de hipersensibilidad a antineoplásicos (Registro nro. 699)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | 02415na a2200253 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | H12O |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20180417112602.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 130622s2012 xxx||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | spa |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 387 |
Nombre de persona | Cortijo Cascajares, Susana |
Término indicativo de función | Farmacia |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 875 |
Nombre de persona | Herreros de Tejada López-Coterilla, Alberto |
Término indicativo de función | Farmacia |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 385 |
Nombre de persona | Jiménez Cerezo, María Jesús |
Término indicativo de función | Farmacia |
245 00 - MENCIÓN DE TÍTULO | |
Título | Revisión de las reacciones de hipersensibilidad a antineoplásicos |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Farmacia Hospitalaria, |
Fecha de publicación distribución etc. | 2012 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 36(3):148-158. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Cortijo-Cascajares S, Jiménez-Cerezo MJ, Herreros de Tejada A. Revisión de las reacciones de hipersensibilidad a antineoplásicos. Farm Hosp. 2012;36(3):148-58. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 22484106 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 105 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | OBJECTIVE: To review the characteristics and management of hypersensitivity reactions caused by antineoplastic agents. METHOD: We conducted a search in the Pubmed and EMBASE databases for the last 10 years. RESULTS: Almost all chemotherapeutic agents have the potential to cause hypersensitivity reactions, but some groups have been associated with increased risk, such as platinum compounds, taxanes, asparaginase, monoclonal antibodies and epipodophyllotoxins. The clinical manifestations of these reactions are variable and unpredictable, including symptoms affecting the skin and the pulmonary, cardiac and gastrointestinal systems. The mechanism associated with their development is not yet fully understood. Diagnosis is based on patients' signs and symptoms and skin testing. The management of patients who suffer a hypersensitivity reaction to a chemotherapeutic agent varies with the severity of the reaction, the need to continue treatment, and the availability of alternative therapies. CONCLUSIONS: Due to a progressive increase in the use of chemotherapeutic agents an increased incidence of hypersensitivity reactions is to be expected. Desensitisation protocols are a noteworthy alternative that make it possible to re-initiate patients' therapy with the causative agent of the hypersensitivity reaction. Their use should be assessed individually, weighing risks and benefits. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 320 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Farmacia Hospitalaria |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/6/pc699.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Suprimido en OPAC | Público |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2016-06-09 | PC699 | 2016-06-09 | 2016-06-09 | Artículo |