245 0 _aType of homogenization and fat loss during continuous infusion of human milk.
_h[artículo]
260 _bJournal of human lactation : official journal of International Lactation Consultant Association,
_c2014
300 _a30(4):436-41.
500 _aFormato Vancouver: García Lara NR, Escuder Vieco D, Alonso Díaz C, Vázquez Román S, De la Cruz Bértolo J, Pallás Alonso CR. Type of homogenization and fat loss during continuous infusion of human milk. J Hum Lact. 2014 Nov;30(4):436-41.
501 _aPMID: 25122692
504 _aContiene 23 referencias
520 _aBackground: Substantial fat loss may occur during continuous feeding of human milk (HM). A decrease of fat loss has been described following homogenization. Well-established methods of homogenization of HM for routine use in the neonatal intensive care unit (NICU) would be desirable. Objective: We compared the loss of fat based on the use of 3 different methods for homogenizing thawed HM during continuous feeding. Methods: Sixteen frozen donor HM samples were thawed, homogenized with ultrasound and separated into 3 aliquots ("baseline agitation," "hourly agitation," and "ultrasound"), and then frozen for 48 hours. Aliquots were thawed again and a baseline agitation was applied. Subsequently, aliquots baseline agitation and hourly agitation were drawn into a syringe, while ultrasound was applied to aliquot ultrasound before it was drawn into a syringe. The syringes were loaded into a pump (2 mL/h; 4 hours). At hourly intervals the hourly agitation infusion was stopped, the syringe was disconnected and gently shaken. During infusion, samples from the 3 groups were collected hourly for analysis of fat and caloric content. Results: The 3 groups of homogenization showed similar fat content at the beginning of the infusion. For fat, mean (SD) hourly changes of -0.03 (0.01), -0.09 (0.01), and -0.09 (0.01) g/dL were observed for the hourly agitation, baseline agitation, and ultrasound groups, respectively. The decrease was smaller for the hourly agitation group (P < .001). Conclusion: When thawed HM is continuously infused, a smaller fat loss is observed when syringes are agitated hourly versus when ultrasound or a baseline homogenization is used.