000 | nab a22 7a 4500 | ||
---|---|---|---|
999 |
_c17365 _d17365 |
||
003 | PC17365 | ||
005 | 20230404134252.0 | ||
008 | 230404b xxu||||| |||| 00| 0 eng d | ||
040 | _cH12O | ||
041 | _aeng | ||
100 |
_92225 _aFontenla Cerezuela, Adolfo _eCardiología |
||
245 | 0 | 0 |
_aShock Reduction With Multiple Bursts of Antitachycardia Pacing Therapies to Treat Fast Ventricular Tachyarrhythmias in Patients With Implantable Cardioverter Defibrillators: A Multicenter Study. _h[artículo] |
260 |
_bJournal of cardiovascular electrophysiology, _c2015 |
||
300 | _a26(7):774-82. | ||
500 | _aFormato Vancouver: Anguera I, Dallaglio P, Martínez Ferrer J, Rodríguez A, Alzueta J, Pérez Villacastín J et al. Shock Reduction With Multiple Bursts of Antitachycardia Pacing Therapies to Treat Fast Ventricular Tachyarrhythmias in Patients With Implantable Cardioverter Defibrillators: A Multicenter Study. J Cardiovasc Electrophysiol. 2015 Jul;26(7):774-82. | ||
501 | _aPMID: 25916814 | ||
504 | _aContiene 29 referencias | ||
520 | _aIntroduction: An empirical sequence of burst antitachycardia pacing (ATP) is effective in terminating fast ventricular tachycardias (FVT) in patients with implantable cardioverter-defibrillators (ICDs). We aimed to determine whether multiple ATP bursts for termination of FVT results in shock reduction compared to a single ATP burst. Methods and results: We analyzed data from the Umbrella trial, a multicenter prospective observational study of ICD patients followed by the CareLink Monitoring System. We compared the safety and effectiveness of a single ATP burst (Group 1) with a strategy of successive ATP sequences (Group 2) for termination of FVT episodes (cycle lengths 250-320 milliseconds) before shock therapy. Over a mean follow-up of 35 months, a total of 650 FVT episodes were detected in 154 patients (mean cycle length: 299 ± 18 milliseconds). Effectiveness of the first burst ATP in Group 1 was 73% and shocks were required in 27% of episodes. Effectiveness of the first burst ATP in Group 2 was 77%, and this increased to 91% with the third or successive ATP bursts. Shocks were required in 9% of episodes in group 2, representing a 67% reduction in the need of high-energy shocks. Median duration of FVT episodes and mortality in both groups were similar. Multivariate analysis indicated that programming multiple ATP bursts (OR 3.4, 95%CI 1.7-6.8, P = 0.001) was an independent predictor of ATP effectiveness. Conclusion: This study provides first evidence that a strategy of multiple burst ATP sequences for termination of FVT episodes leads to a clinically meaningful reduction in the need for shocks. | ||
710 |
_9119 _aServicio de Cardiología |
||
856 |
_uhttp://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc17365.pdf _ySolicitar documento |
||
942 |
_2ddc _cART _n0 |