000 02546na a2200265 4500
999 _c7271
_d7271
003 PC7271
005 20181115114617.0
008 130622s2013 xxx||||| |||| 00| 0 eng d
040 _cH12O
041 _aspa
100 _aCasas Martin, A. I.
_92434
_eMedicina Intensiva
100 _aFernández Gaute, Nieves
_92018
_eMedicina Intensiva
100 _aFernandez Jimenez, A.
_92435
_eMedicina Intensiva
100 _aFernandez Miralles, M. J.
_92436
_eMedicina Intensiva
100 _aFrade Mera, María Jesús
_91295
_eMedicina Intensiva
100 _aMontejo González, Juan Carlos
_9874
_eMedicina Intensiva
100 _aMontes Gil, Diego
_92019
_eMedicina Intensiva
100 _aVergara Díez, Laura
_92020
_eMedicina Intensiva
245 0 0 _aProfundizando en el conocimiento sobre el manejo del dispositivo para control de la eliminación fecal en el paciente crítico.
_h[artículo]
260 _bEnfermeria intensiva,
_c2013
300 _a24(1):23-35.
500 _aFormato Vancouver: Frade Mera MJ, Vergara Díez L, Fernández Gaute N, Casas Martín AI, Montes Gil D, Fernández Miralles MJ et al. Profundizando en el conocimiento sobre el manejo del dispositivo para control de la eliminación fecal en el paciente crítico. Enferm Intensiva. 2013 Jan-Mar;24(1):23-35.
501 _aPMID: 23347729
504 _aContiene 84 referencias
520 _aOBJECTIVE: To describe the general characteristics of the patient and device use. To know retention balloon pressure (RBP) and related factors. To identify rate of leakage incidence, relocation and perineal damage due to the device (PSD) and related risk factors. MATERIAL AND METHODS: An analytical observational, cross-sectional study conducted in a polyvalent ICU from June-December 2010 was performed. The sample included Flexi-Seal() carriers. Variables evaluated were patient and device use characteristics, RBP, leakage and quantity, relocation and reason, PSD, sedoanalgesia infusion, neuromuscular block, patient position, Flexi-Seal type catheter, ventilatory mode (VM), intra-abdominal pressure (IAP), mean intrathoracic pressure (MITP), PEEP, Glasgow, color-aspect, fecal consistency and volume. Significance P<.05. RESULTS: Twenty-one patients were included, 52% male, aged 5417 with 30 insertion episodes, Flexi-Seal-Signal() 33%, 108 days permanency, main indication 33% diarrhea and injured skin," 30% device removal intolerance and/or spontaneous expulsion. Median (Me) PGR =40; RI (61-19) cmH2O. Factors associated to higher PGR: SCI absence, prone-decubitus position, leakage, relocation, conventional Flexi-Seal(), MV, lower PEEP and IMP, Color-aspect, higher MITP. Leakage, relocation and PSD incidence density 43, 30 and 2 cases/100 days of catheter, respectively. Leakage and relocation risk factors: higher PGR, Glasgow and fecal volume, lower MITP, MV, assisted-spontaneous mode OR 2.5 CI (1.6-3.8) and OR 1.7(1.1-2.7), absence SCI OR 3.3 (2.2-5.1) and OR 2.4(1.5-3.8), absence neuromuscular block OR 2.4 (1.4-3.9) and OR 1.8 (1.1-3.1), Flexi-Seal() conventional
710 _967
_aServicio de Medicina Intensiva
856 _uhttp://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/7/pc7271.pdf
_ySolicitar documento
942 _n0
_2ddc
_cART