000 | 02546na a2200265 4500 | ||
---|---|---|---|
999 |
_c7271 _d7271 |
||
003 | PC7271 | ||
005 | 20181115114617.0 | ||
008 | 130622s2013 xxx||||| |||| 00| 0 eng d | ||
040 | _cH12O | ||
041 | _aspa | ||
100 |
_aCasas Martin, A. I. _92434 _eMedicina Intensiva |
||
100 |
_aFernández Gaute, Nieves _92018 _eMedicina Intensiva |
||
100 |
_aFernandez Jimenez, A. _92435 _eMedicina Intensiva |
||
100 |
_aFernandez Miralles, M. J. _92436 _eMedicina Intensiva |
||
100 |
_aFrade Mera, María Jesús _91295 _eMedicina Intensiva |
||
100 |
_aMontejo González, Juan Carlos _9874 _eMedicina Intensiva |
||
100 |
_aMontes Gil, Diego _92019 _eMedicina Intensiva |
||
100 |
_aVergara Díez, Laura _92020 _eMedicina Intensiva |
||
245 | 0 | 0 |
_aProfundizando en el conocimiento sobre el manejo del dispositivo para control de la eliminación fecal en el paciente crítico. _h[artículo] |
260 |
_bEnfermeria intensiva, _c2013 |
||
300 | _a24(1):23-35. | ||
500 | _aFormato Vancouver: Frade Mera MJ, Vergara Díez L, Fernández Gaute N, Casas Martín AI, Montes Gil D, Fernández Miralles MJ et al. Profundizando en el conocimiento sobre el manejo del dispositivo para control de la eliminación fecal en el paciente crítico. Enferm Intensiva. 2013 Jan-Mar;24(1):23-35. | ||
501 | _aPMID: 23347729 | ||
504 | _aContiene 84 referencias | ||
520 | _aOBJECTIVE: To describe the general characteristics of the patient and device use. To know retention balloon pressure (RBP) and related factors. To identify rate of leakage incidence, relocation and perineal damage due to the device (PSD) and related risk factors. MATERIAL AND METHODS: An analytical observational, cross-sectional study conducted in a polyvalent ICU from June-December 2010 was performed. The sample included Flexi-Seal() carriers. Variables evaluated were patient and device use characteristics, RBP, leakage and quantity, relocation and reason, PSD, sedoanalgesia infusion, neuromuscular block, patient position, Flexi-Seal type catheter, ventilatory mode (VM), intra-abdominal pressure (IAP), mean intrathoracic pressure (MITP), PEEP, Glasgow, color-aspect, fecal consistency and volume. Significance P<.05. RESULTS: Twenty-one patients were included, 52% male, aged 5417 with 30 insertion episodes, Flexi-Seal-Signal() 33%, 108 days permanency, main indication 33% diarrhea and injured skin," 30% device removal intolerance and/or spontaneous expulsion. Median (Me) PGR =40; RI (61-19) cmH2O. Factors associated to higher PGR: SCI absence, prone-decubitus position, leakage, relocation, conventional Flexi-Seal(), MV, lower PEEP and IMP, Color-aspect, higher MITP. Leakage, relocation and PSD incidence density 43, 30 and 2 cases/100 days of catheter, respectively. Leakage and relocation risk factors: higher PGR, Glasgow and fecal volume, lower MITP, MV, assisted-spontaneous mode OR 2.5 CI (1.6-3.8) and OR 1.7(1.1-2.7), absence SCI OR 3.3 (2.2-5.1) and OR 2.4(1.5-3.8), absence neuromuscular block OR 2.4 (1.4-3.9) and OR 1.8 (1.1-3.1), Flexi-Seal() conventional | ||
710 |
_967 _aServicio de Medicina Intensiva |
||
856 |
_uhttp://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/7/pc7271.pdf _ySolicitar documento |
||
942 |
_n0 _2ddc _cART |